Panel Ace Sectional Door Opener





Technical Overview
The Auto Openers Panel Ace is designed for sectional and panel garage doors up to 16.5m². With a 1000N motor, smooth belt drive, and quiet operation, it’s the ideal solution for attached garages or homes where noise reduction matters.
Included in the Box
- Auto Openers “Panel Ace” Garage Door Opener
- 3x AOTXv2 Keyring Transmitters
- 3.2m Belt Rail (3-piece rail)
- Video Installation Instructions
- 5 Year Warranty
Specifications & Features
Frequently Asked Questions
How do I activate/deactivate my remote?
To program a remote into your opener:
- Press and hold the “CODE” button until the Coding LED illuminates, then release.
- Press and hold a button on your remote for 2 seconds, then release. The Coding LED will extinguish.
- Press and hold the same button again. The Coding LED will flash and the opener will beep to confirm the remote has been programmed.
- Test the operation of your remote.
To delete all remotes from your opener:
- Press and hold the “CODE” button. The Coding LED will flash 8 times, then “C” will appear on the display and the opener will beep.
- Test to ensure your removed remote no longer operates the opener.
Where do I get a replacement/additional remotes?
We pair with a number of leading online retailers, who can ship your remote if purchased online. View our list of resellers here.
Otherwise, please call us on 1300 42 88 66 to find your local Auto Openers Accredited Dealer.
How do I open my sectional door opener manually?
Pull the handle on the bottom of your opener to disengage the motor. This will allow you to manually open the sectional door.
I cannot program my remote.
Please ensure that the door limits have been set in the opener. You can view our installation video here which shows how to reset the limits: Watch installation video.
How do I turn PE Beams on or off?
To enable PE Beams, set the opener to Setting “11”, press “UP” for “H”, then press “SET” to confirm.
To disable PE Beams, return to “11” and press “SET”.
How do I enable or disable Auto Close?
To turn on Auto Close, go to Setting “- -” and adjust the timing. Maximum time is 9 (PE Beams must be fitted). To turn Auto Close off, set the timing to “0”.
How do I adjust the Force Settings?
Press and hold “SET” until the LED displays “3”, then release.
Use “UP” and “DOWN” to adjust the Force setting (1 is lowest, 9 is highest).
Press “SET” to save.